4. TROUBLE SHOOTING
- 54 -
START
I/O Connector(CN300)
Is well-soldered ?
Voltage at anode of
D101 = 5.2V ?
Q102,D101,R129 are
well-soldered?
YES
YES
YES
Voltage across R129 is
about 10~100mV?
YES
0.7V < voltage(R131) < 1.3V?
YES
Battery is charged?
YES
Charging is
properly operating
NO
NO
NO
NO
NO
NO
Resolder the CN300
Pin 4,5 : VCHARGE
Pin12,19 : GND
The TA is out of order
Change the TA
Resolder the
Q102, D101, R129
Replace the
Q102 , D101
Replace the
Q102
The battery may have
problems.
Change the battery.