4. TROUBLE SHOOTING
- 56 -
SETTING : Enter the engineering mode, and set vibrator on at vibration of BB test menu
START
Is the voltage at pin 3
of Q100 high ?
YES
NO
Resolder R105, R106
Is the voltage at pin 2
of Q100 low ?
YES
Is the voltage at pin 1
of Q100 high ?
YES
Check the soldering
of CN600 ?
YES
Check the soldering
of vibrator ?
YES
Replace vrbrator
YES
Vibrator
Working well !
Check the soldering
of R105, R106
YES
NO
Resolder R101
Check the soldering
of R101
YES
NO
NO
NO
Resolder CN600
Check the soldering
of R103
YES
NO
Resolder R103
Replace Q100
NO
Resolder vibrator
NO
Checking Flow