4. TROUBLE SHOOTING
- 70 -
START
Does waveform at
R133 and R135
fluctuate?
NO
Replace main board
YES
Is CN600 connected
properly?
NO
YES
Receiver will work properly.
SETTING : After initialize Agilent 8960, Test EGSM, DCS mode
Set the property of audio as PRBS or continuous wave. Set the receiving volume of mobile as Max.
Is receiver connected
Properly?
YES
Reassemble CN600
NO
Resoldering receiver
Checking Flow