4. TROUBLE SHOOTING
- 40 -
(2) Checking FEM & Mobile SW
X500.3
(OUT)
X500.4
(VCC)
X500
Check Pin 3.
Refer to Graph 4 -1(b)
26 MHzO.K?
No
No
VCTCXO Circuit is OK
See next Page to check
Mobile SW
VCTCXO Circuit is OK
See next Page to check
Mobile SW
Yes
Check Pin 4.
Refer to Graph 4- 1(a)
2.75V OK?
No
Yes
Changing X500
Check U101
1000p
C543
100
R520
R521
15K
2V75_VVCXO
C542
NA
GND
2
OUT
3
4
VCC
1
VCONT
X500
26MHz
C544
2.2u
AFC
TEST POINT
CIRCUIT
Waveform
Checking Flow
Graph 1(a)