12. AUTO CALIBRATION
12. AUTO CALIBRATION
LGE Internal Use Only
12.1 Overview
Auto-cal (Auto Calibration) is the PC side Calibration tool that perform Tx, Rx and Battery Calibration with Agilent
8960(GSM call setting instrument) and Tektronix PS2521G(Programmable Power supply).
Auto-cal generates calibration data by communicating with phone and measuring equipment then write it into
calibration data block of flash memory in GSM phone.
12.2 Equipment List
Equipment for Calibration
Type / Model
Band
Wireless Communication Test Set
HP-8960
Agilent
RS-232 Cable and Test JIG
LG
RF Cable
RF-800
LG
Power Supply
HP-66311B
Agilent
GPIO interface card
HP-GPIB
Agilent
Calibration & Final test software
LG
Test SIM Card
PC (for Software Installation)
Pentium
Ⅱ
class above 300MHz
Table 12-1. Calibration Equipment List.
Figure 12-1. Equipment Setup