35
8
GAS REQUIREMENTS AND INSTRUCTIONS
Following are important instructions and information concerning the requirements for the gas supply and service for
gas dryers.
IMPORTANT WARNING:
The gas supply and service for a gas dryer must comply with all local
codes and ordinances. In the absence of any local codes or ordinances in your area, the gas supply and
service for your gas dryer must comply with the latest edition of the National Fuel Gas Code, ANSI Z223.1/
NFPA 54(USA) or Canadian gas installation code CAS B149.1(Canada).
1. Gas supply requirements: Liquefied
Petroleum (L.P.) Gas (2,500 Btu/ft3 (93.1
MJ/m3)) service must be provided at 10 +
1.5 in. water column pressure.
2. Do not attempt to connect the dryer to
Liquified Petroleum (LP Gas) Gas service
without a qualified professional.
3. Isolate the dryer from the gas supply piping
system by closing its individual manual shut-
off valve during any pressure testing of the
gas supply system at test pressure equal to
or less than 1/2 psi (3.45 kPa).
4. Supply Line Requirements. Your laundry
room must have a rigid gas supply line to
your dryer. In the United States, an
individual manual shutoff valve MUST be
installed within at least 6 feet (1.8 m) of the
dryer, in accordance with the National Fuel
Gas Code ANSI Z223.1 or Canadian gas
installation code CSA B149.1.
A 1/8 in. N.P.T. pipe plug must be installed as
shown.
5. If using a rigid pipe, the rigid pipe should be 1/2
inch IPS. If acceptable under local codes and
ordinances and when acceptable to your gas
supplier, 3/8 inch approved tubing may be used
where lengths are less than 20 feet (6.1 m).
Larger tubing should be used for lengths in
excess of 20 feet (6.1 m). It is also important that
you use pipe joint compound that is insoluble in
LP gas.
6. To reduce the danger of gas leaks, explosion,
and fire, please follow and observe the following
instructions and WARNINGS.
• Connect the dryer to the type of gas shown on the
nameplate.
• Use new flexible stainless steel connectors.
• Use Teflon tape and pipe joint compound insoluble
in LP gas on all pipe threads.
• Purge gas supply of air and sediment before
connecting the gas supply to the dryer in order to
prevent gas valve contamination. Before tightening
connection between gas supply and dryer, purge
remaining air until odor of gas is identified.
• DO NOT use an open flame to inspect for gas leaks;
instead use a non-corrosive leak detection fluid.
WARNING
•
Use a new AGA or CSA approved gas supply
line.
•
Install a shut-off valve.
•
Securely tighten all gas connections.
•
If connected to LP, have a qualified person
make sure gas pressure does not exceed 13
in. water column.
•
Examples of a qualified person include
licensed heating personnel, authorized gas
company personnel, and authorized service
personnel.
•
Failure to do so can result in death, explosion,
or fire.
WARNING
•
Do not attempt any disassembly of the
dryer. Any disassembly requires the
attention and tools of an authorized and
qualified service person or company.
•
Failure to do so can result in
death,explosion, or fire.
Содержание GDL1329CED3
Страница 13: ...13 4 INITIAL STEPS FOR INSTALLING YOUR DRYER ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 27: ...27 Stacking Card Different point between Coin type and Card type Installation Method Card Type 4 ...
Страница 28: ...28 ...
Страница 29: ...29 6 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS ...
Страница 36: ...36 9 EXHAUST REQUIREMENTS AND MAINTENANCE ...
Страница 40: ...40 10 DRYER CYCLE PROCESS ...
Страница 42: ...42 44 ...
Страница 43: ...43 ...
Страница 44: ...44 12 MOTOR DIAGRAM AND SCHEMATIC Centrifugal switch Centrifugal switch Pull Drive forward ...
Страница 45: ...45 13 CONTROL LAY OUT PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Страница 50: ...50 ...
Страница 51: ...51 Trouble Symptom Measurement Condition Air TEMP RES k Air TEMP RES k Air TEMP RES k ...
Страница 53: ...53 Trouble Symptom Measurement Condition IMC Display Value Voltage DC between 6 Pin terminal Remark ...
Страница 55: ...55 Trouble Symptom Measurement Condition ...
Страница 56: ...56 Trouble Symptom Measurement Condition ...
Страница 57: ...57 16 ERROR MODE ...
Страница 61: ...61 18 CHANGE GAS SETTING NATURAL GAS PROPANE GAS ...
Страница 62: ...62 ...
Страница 71: ...71 EXPLODED VIEW 20 20 1 1 Control Panel Plate Assembly Coin OPL Type A210 A120 A116 A110 ...
Страница 72: ...72 20 1 2 Control Panel Plate Assembly Card Type A210 A120 A117 A116 A110 ...
Страница 79: ...MAR 2018 PRINTED IN KOREA P No MFL68921845 ...