18
The following instructions are applicable to
installations of the dryer in a manufactured or
mobile home. Any installation in a
manufactured or mobile home must comply
with the Manufactured Home Construction and
Safety Standards Title 24 CFR, Part 32-80 or
Standard CAN/CSA0Z240 MH and local codes
and ordinances. If you are uncertain whether
your proposed installation will comply with
these standards, please contact a service and
installation professional for assistance.
The following instructions apply to any
installation of the dryer in a manufactured or
mobile home:
1) The gas dryer must be permanently
attached to the floor.
2) The electrical connection for an electric
dryer must be a 4-wire connection. More
detailed information concerning the electrical
connection is provided at the manual section
entitled Electrical Requirements for Electric
Dryer
3) To reduce the risk of combustion and fire,
the dryer must be vented to the outside.
4) Electric dryers may be vented to the outside
using the back, left, right, or bottom panel.
5) Gas dryers may be vented to the outside
using the back, left, or bottom panel. Gas
dryer may not be vented to the outside using
the right side panel because of the burner
housing.
6) The dryer exhaust duct must be affixed
securely to the manufactured or mobile
home structure, and the exhaust duct must
be made of a material that will resist fire and
combustion, and it is recommended that you
use a rigid or flexible metal pipe.
7) DO NOT connect the exhaust duct with any
other duct, vent, chimney, or other exhaust
duct.
8) Make sure the dryer has adequate access to
outside fresh air to ensure proper operation.
The opening for outside fresh air must be at
least 25 in2 (163 cm2).
9) It is important that the clearance of the duct
from any combustible construction be at
least 2 inches (5 cm), and, when venting the
dryer to the outdoors, the dryer can be
installed with a clearance of 1 inch at the
sides and back of the dryer.
10) Please be aware that venting materials are
not supplied with the dryer. You should
obtain the venting materials necessary for
proper installation.
WARNING
Do not connect exhaust ducts with
metal screws or fasteners that extend
into the duct.
WARNING
Do not vent the exhaust duct under the
manufactured or mobile home.
STEP 9
Additional Instructions
for Installation of Your
Dryer in a Manufactured
or Mobile Home.
Содержание GDL1329CED3
Страница 13: ...13 4 INITIAL STEPS FOR INSTALLING YOUR DRYER ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 27: ...27 Stacking Card Different point between Coin type and Card type Installation Method Card Type 4 ...
Страница 28: ...28 ...
Страница 29: ...29 6 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS ...
Страница 36: ...36 9 EXHAUST REQUIREMENTS AND MAINTENANCE ...
Страница 40: ...40 10 DRYER CYCLE PROCESS ...
Страница 42: ...42 44 ...
Страница 43: ...43 ...
Страница 44: ...44 12 MOTOR DIAGRAM AND SCHEMATIC Centrifugal switch Centrifugal switch Pull Drive forward ...
Страница 45: ...45 13 CONTROL LAY OUT PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Страница 50: ...50 ...
Страница 51: ...51 Trouble Symptom Measurement Condition Air TEMP RES k Air TEMP RES k Air TEMP RES k ...
Страница 53: ...53 Trouble Symptom Measurement Condition IMC Display Value Voltage DC between 6 Pin terminal Remark ...
Страница 55: ...55 Trouble Symptom Measurement Condition ...
Страница 56: ...56 Trouble Symptom Measurement Condition ...
Страница 57: ...57 16 ERROR MODE ...
Страница 61: ...61 18 CHANGE GAS SETTING NATURAL GAS PROPANE GAS ...
Страница 62: ...62 ...
Страница 71: ...71 EXPLODED VIEW 20 20 1 1 Control Panel Plate Assembly Coin OPL Type A210 A120 A116 A110 ...
Страница 72: ...72 20 1 2 Control Panel Plate Assembly Card Type A210 A120 A117 A116 A110 ...
Страница 79: ...MAR 2018 PRINTED IN KOREA P No MFL68921845 ...