Remove the terminal block access cover
on the upper back of the dryer. Install a
UL-listed strain relief into the power cord
through-hole; then thread a UL-listed, 30A,
240V, 4-wire, #10 AWG-minimum copper
conductor power cord through the
strain relief.
Transfer the dryer’s ground wire from behind
the green ground screw to the center screw
of the terminal block. Attach the two hot
leads of the power cord to the outer terminal
block screws. Attach the white neutral wire
to the center terminal block screw. Attach the
power cord ground wire to the green ground
screw. TIGHTEN ALL SCREWS SECURELY.
Reinstall the terminal block access cover.
UL-Listed
Strain Relief
UL-Listed
4-Wire
Power Cord
Terminal
Block
Ground Screw
Neutral
(White)
Hot
(Black)
Power Cord
Ground Wire
Hot
(Red)
• A 4-wire connection is required for all mobile
and manufactured home installations, as well
as all new construction after January 1, 1996.
• A UL-listed strain relief is required.
• Use a 30-amp, 240V, UL-listed power cord
with #10 AWG-minimum copper conductor
and closed loop or forked terminals with
upturned ends.
WARNING:
Connect the power co r d to the terminal block. Each colo r ed wi r e should be connected to
same color sc r e w . Wi r e color indicated on manual is connected to the same color sc r ew
in block. Failu r e to follow these instructions may r esult in a short or overload.
G r ounding th r ough the neutral conductor is p r ohibited for: (1) new branch-ci r cuit
installations, (2) mobile homes, (3) r ec r eational vehicles, and (4) a r eas whe r e local
codes p r ohibit g r ounding th r ough the neutral conducto r .
!
Содержание GDL1329CED3
Страница 13: ...13 4 INITIAL STEPS FOR INSTALLING YOUR DRYER ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 27: ...27 Stacking Card Different point between Coin type and Card type Installation Method Card Type 4 ...
Страница 28: ...28 ...
Страница 29: ...29 6 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS ...
Страница 36: ...36 9 EXHAUST REQUIREMENTS AND MAINTENANCE ...
Страница 40: ...40 10 DRYER CYCLE PROCESS ...
Страница 42: ...42 44 ...
Страница 43: ...43 ...
Страница 44: ...44 12 MOTOR DIAGRAM AND SCHEMATIC Centrifugal switch Centrifugal switch Pull Drive forward ...
Страница 45: ...45 13 CONTROL LAY OUT PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Страница 50: ...50 ...
Страница 51: ...51 Trouble Symptom Measurement Condition Air TEMP RES k Air TEMP RES k Air TEMP RES k ...
Страница 53: ...53 Trouble Symptom Measurement Condition IMC Display Value Voltage DC between 6 Pin terminal Remark ...
Страница 55: ...55 Trouble Symptom Measurement Condition ...
Страница 56: ...56 Trouble Symptom Measurement Condition ...
Страница 57: ...57 16 ERROR MODE ...
Страница 61: ...61 18 CHANGE GAS SETTING NATURAL GAS PROPANE GAS ...
Страница 62: ...62 ...
Страница 71: ...71 EXPLODED VIEW 20 20 1 1 Control Panel Plate Assembly Coin OPL Type A210 A120 A116 A110 ...
Страница 72: ...72 20 1 2 Control Panel Plate Assembly Card Type A210 A120 A117 A116 A110 ...
Страница 79: ...MAR 2018 PRINTED IN KOREA P No MFL68921845 ...