33
Remove inches (8.9cm) of the outer covering
from the wire. Strip 1 inch (2.5cm) insulation from
each wire. Bend the ends of the three wires into a
hook shape.
2
1
Attach the two hot leads of the power cord to the
outer terminal block screws. Attach the neutral wire
to the center terminal block screw. Connect the
external ground (If required by local codes) to the
green ground screw. TIGHTEN ALL SCREWS SEVURELY.
Reinstall the terminal block access cover.
3
G round Sc rew
Neutral
(White)
Hot
(Black)
G round Wire
Hot
(Red)
Remove the terminal block access cover on the
upper back of the dryer. Install a UL-listed strain
relief into the power cord through-hole; then
thread the power cable prepared in Step 1 through
the strain relief.
2
UL-Listed
Strain Relief
UL-Listed
3-Wi re
Power Co rd
Terminal
Block
1" (2.5 cm)
construction after January 1, 1996.
conductor cable.
removal and reinstallation of the dryer.
WARNING:
Connect the power cord to the terminal block. Each colored wire should be connected to same color
screw. Wire color indicated on manual is connected to the same color screw in block. Failure to follow
these instructions may result in a short or overload.
Grounding through the neutral conductor is prohibited for: (1) new branch-circuit instrallations,
(2) mobile homes, (3) recreational vehicles and (4) areas where local codes prohibit grounding
through the neutral conductor.
!
3
1
Содержание GDL1329CED3
Страница 13: ...13 4 INITIAL STEPS FOR INSTALLING YOUR DRYER ...
Страница 14: ...14 ...
Страница 15: ...15 ...
Страница 16: ...16 ...
Страница 17: ...17 ...
Страница 27: ...27 Stacking Card Different point between Coin type and Card type Installation Method Card Type 4 ...
Страница 28: ...28 ...
Страница 29: ...29 6 ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYERS ...
Страница 36: ...36 9 EXHAUST REQUIREMENTS AND MAINTENANCE ...
Страница 40: ...40 10 DRYER CYCLE PROCESS ...
Страница 42: ...42 44 ...
Страница 43: ...43 ...
Страница 44: ...44 12 MOTOR DIAGRAM AND SCHEMATIC Centrifugal switch Centrifugal switch Pull Drive forward ...
Страница 45: ...45 13 CONTROL LAY OUT PWB ASSEMBLY DISPLAY LAY OUT PWB ASSEMBLY LAY OUT ...
Страница 50: ...50 ...
Страница 51: ...51 Trouble Symptom Measurement Condition Air TEMP RES k Air TEMP RES k Air TEMP RES k ...
Страница 53: ...53 Trouble Symptom Measurement Condition IMC Display Value Voltage DC between 6 Pin terminal Remark ...
Страница 55: ...55 Trouble Symptom Measurement Condition ...
Страница 56: ...56 Trouble Symptom Measurement Condition ...
Страница 57: ...57 16 ERROR MODE ...
Страница 61: ...61 18 CHANGE GAS SETTING NATURAL GAS PROPANE GAS ...
Страница 62: ...62 ...
Страница 71: ...71 EXPLODED VIEW 20 20 1 1 Control Panel Plate Assembly Coin OPL Type A210 A120 A116 A110 ...
Страница 72: ...72 20 1 2 Control Panel Plate Assembly Card Type A210 A120 A117 A116 A110 ...
Страница 79: ...MAR 2018 PRINTED IN KOREA P No MFL68921845 ...