57
LD Check.
OK
Does Focus Servo
operate normally?
OK
Recognition Fail Case1:
CD-ROM Fail.
Go to “LD Control is abnormal”.
Replace Unit Mecha and execute
LD calibration.
NG
Go to “Focus Servo is unstable”.
NG
Does Tracking Servo
operate normally?
OK
NG
Check
Pickup RF signal(TL313-315,317)
was 200~800mVpp?
Go to “Tracking Servo is unstable”.
NG
1)Check Soldering of PG301.
2) Check voltage of TL311(5V).
3) Check voltage of TL320(2.5V).
4) Check voltage of TL332(2.1)
5) Check insertion or damage of
Main FPC.
OK
Is there WBL(TL117) signal?
Is there
WBLI(IC201B14) signal?
Recognition Fail Case1:
Blank CD-R/RW Fail.
Replace IC101
Replace IC201.
NG
OK
OK