B304 Cell Voltage Imbalance
Fault
Cell Voltage differences between
the battery cells are higher than
500mV
Contact service center
B305 Pack Over Voltage
Fault
Pack Voltage level of battery packis
higher than 241V
Contact service center
B306 Pack Under Voltage
Fault
Pack Voltage level of battery pack
is lower than 160V
Contact service center
B307 Over Charge Current
Fault
Current level of charging is higher
than 22.5A
Contact service center
B308 Over Discharge
Current Fault
Current level of discharging is
higher than 22.5A
Contact service center
B309 Over Temperature
fault
The battery temperature is higher
than 50°C
Contact service center
B310 Under Temperature
fault
The battery temperature is lower
than -15°C
Contact service center
B311 Temperature
Deviation Fault
Temperature differences between
the battery are over 10°C
Contact service center
B312 Current Sensor Offset
Error
Fault has been detected on the
current sensor
Contact service center
B313 External
Communication Error
Communication error has been
detected between the battery and
the PCS
Contact service center
B314 External 12V Power
Error
The power is not supplied to the
battery from the PCS
Contact service center
B315 Internal
Communication Error
Internal communication error has
been detected for 10sec
Contact service center
B316 Current Sensor Line
Error
Current Sensor Line Error
Contact service center
B317 Temperature Sensor
Error
Temperature sensor error
Contact service center
B318 MBMS MCU-Battery
Monitoring IC Comm.
Error
MBMS MCU-Battery Monitoring IC
Comm. Error
Contact service center
B319
RBMS Ref V Error
Voltage level of the battery
management system is higher than
the protection limitation.
Contact service center
B320 MBMS ADC Reference
Voltage Error
MBMS ADC Reference Voltage
Error
Contact service center
Содержание D005KD1N111
Страница 84: ......
Страница 97: ...End user 2 4 1 1 1 3 13 3 8 Accept terms Owner checks Select All and select AGREE ...
Страница 113: ...Appendix Installer 29 3 9 f Select OK button Installer can check that another installer has been registered like below ...
Страница 115: ...Appendix Installer 31 5 9 Installer terms New installer must select the 2 boxes I agree and the button Submit ...
Страница 119: ...Appendix Installer 35 9 9 f Click Company Information Installer can check that a subsidiary has been registered f ...
Страница 120: ......
Страница 204: ......
Страница 217: ...Endverbraucher 2 4 1 1 1 3 13 3 8 Annahme der Geschäftsbedingungen Der Kunde wählt Alle auswählen und ZUSTIMMEN ...
Страница 240: ......
Страница 324: ......
Страница 360: ......
Страница 444: ......
Страница 457: ...Eindgebruiker 2 4 1 1 1 3 13 3 8 Voorwaarden accepteren De eigenaar schakelt Alles selecteren in en kiest ACCEPTEREN ...
Страница 480: ......