17
206-4157
System Setup (Cont.)
(Continued from previous page)
c) If you changed the time zone and/or the NTP configuration, you will be prompted to reset
the system. When you have completed your date and time configuration activities, at the
Command >
prompt, type
reset
and press
Enter
. The reset process may take up to two
minutes, after which the PCS150R resumes normal operation.
10. Make the appropriate connection to the RF distribution system or IP distribution network
depending on the PCS150R output option to be used.
• ASI output: Connect the RF output on the upconverter to the RF distribution center
combiner, and balance the RF signal so that the Pro:Centric signal level at the TV(s) is
between 0 to +7 dBmV.
• RF output: Connect RF OUT on the PCS150R to the RF distribution center combiner,
and balance the RF signal so that the Pro:Centric signal level at the TV(s) is between 0
to +7 dBmV.
• IP output: Connect a CAT5E or better Ethernet cable between the ETHERNET-1 port on
the PCS150R rear panel and the institution’s IP distribution network.
Caution (ASI/RF Output only): For proper system performance, the Pro:Centric
signal level at the TV input (ANTENNA IN) must be between 0 to +7 dBmV. Note
that additional equipment may be required to adjust the signal level.
11. Configure the ASI/RF or IP output parameters in the Pro:Centric server Admin Client “RF/
IP Configuration” screen. Refer to the
Pro:Centric Server Admin Client User Guide
for
further information.
Note:
By default, the server output is enabled for QAM-B modulation (RF output).
12. Check one or more room receivers to make sure all content is properly mapped and
available.