16
206-4157
System Setup (Cont.)
(Continued from previous page)
e) When you are finished with network configuration, type
exit
and press
Enter
at the
Network Configuration Menu
>
prompt. The system will display an overview of the new
network configuration and then prompt for confirmation to save the changes:
Do you want to save the new configuration? (Y/N):
Type
y
or
n
and press
Enter
, as appropriate.
Note:
Review the New Network Configuration overview carefully before you confirm the
configuration settings. Ensure each of the addresses was entered correctly.
f) If you changed the configuration of the port(s), you will be prompted to reset the system.
At the
Command >
prompt, type
reset
and press
Enter
. The reset process may take up
to two minutes, after which the PCS150R resumes normal operation.
9. (Optional) Set the date and time on the PCS150R.
By default, the PCS150R is synchronized with an NTP client and configured for the US
Eastern time zone. If the PCS150R is connected to the Internet, the NTP client will periodi-
cally update the time setting on the PCS150R. You can set the time zone as required. If the
PCS150R is not connected to the Internet, you also have the option to disable NTP client
synchronization and specify date and time data manually.
Note:
The Time setup (“time”) command indicated below is available only with PCS150R
version 5.2 or later software. (Check the System Information display header, as necessary,
to verify the PCS150R software version.)
a) This step requires that you log in to the PCS150R.
• If you are already logged in, continue with step (b).
• Otherwise, below the System Information display (after boot-up), you should see a
login prompt. (If the prompt is not automatically displayed, press
Enter
to refresh the
screen.)
At the
login as:
prompt, type
admin
and press
Enter
. Then, type the admin user
password (provided by LG) at the
password:
prompt.
b) Use the PCS150R “tz” and/or “time” commands, as necessary, to set the date and time
on the PCS150R.
• Use the “tz” command and follow the system prompts to change the time zone.
• Use the “time” command and follow the system prompts to change the NTP
configuration or manually configure the date and time parameters on the PCS150R.
Refer to “Set the Time Zone” and “Set the Date and Time,” respectively, on pages 24 to 27
for further information on these commands.
(Continued on next page)