Installer Setting -Optional Function Setting
Optional Operation
This function is used when air Cleaner, heater, humidifier, elevation grill, ventilation KIT are installed
additionally or the installed KIT is removed.
Select the code value and set value for each function using
F G
button.
Press and hold
B
button for more than 3 seconds to enter the installer settings mode.
- If pressing only once briefly, it will enter the user settings mode.
Make sure to press and hold for more than 3 seconds.
Press
B
button repeatedly to move to the applicable Function in the menu as below.
Press
K
button to save the setting.
Press
L
button to exit.
h
If no button is selected for about 25 seconds after setup, it exits the setup mode automatically.
h
If
K
button is not selected before you exit, the changes will not apply.
Code value
Set value
❈
Set value for each function
00 : Not installed
01 : Installed
Function
Code
Plasma purification
20
Electric heater
21
Humidifier
22
Elevation grill
23
Ventilation kit
24
Auxiliary heater
25
h
In case of indoor unit that has one more additional stage in the Aux heater setting.
00: not installed
01: installed - general
02: installed - duct type