Universal System Air Conditioner
Ceiling Cassette 4-way
3. Specifications
Conversion Formula
kW
= Btu/h
×
0.0002931
kcal/h = Btu/h
×
0.252
CFM = CMM
×
35.3
Power Supply
Ø/V/Hz
Cooling Capacity
kW
Btu/h
Heating Capacity
kW
Btu/h
Current
Nominal running current
A
Fan
Motor Type
Fan Type
Motor Output x Number of Unit
Air Flow Rate
cmm
(H/M/L)
cfm
Capacitor
µF/Vac
Drive
Coil
Row x Column x FPI
mm
Dimensions
Body
mm(inch)
(WxHxD)
Decorative Panel
mm
Weight
Body
kg(lbs)
Decorative Panel
kg(lbs)
Air Filter
Sound Level (H/M/L)
dB(A)+3
Piping
Liquid
mm(inch)
Connections
Gas
mm(inch)
Drain(OD/ID)
mm
Dehumidification Rate
l/h
Safety devices
Temperature Sensor
Referigerant
Referigerant Control
Connectable outdoor unit
Power and transmission interunit cable
No.x mm
2
Model
ATNH366DLFC
[UT36 NDC]
ATNH426DLFC
[UT42 NDC]
ATNH486DLFC
[UT48 NDC]
ATNH606DLFC
[UT60 NDC]
Indoor unit type
Ceilling Cassette - 4way
1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50 1 / 220 ~240 / 50
9.5
11.9
12.9
14.2
32,500
40,500
44,000
48,500
10.8
13.3
14.5
15.9
37,000
45,500
49,500
54,500
0.76
1.2
1.5
1.8
Induction
Induction
Induction
Induction
Turbo Fan
Turbo Fan
Turbo Fan
Turbo Fan
52.5*1
55*1
58.5*1
107*1
25 / 23 / 21
29 / 26 / 23
30 / 28 / 26
34 / 32 / 30
883 / 812 / 742
1023 / 918 / 812
1059 /988 / 918
1200 / 1130 / 1059
4/440
6/400
6/400
6/400
Direct Drive
Direct Drive
Direct Drive
Direct Drive
2R x 12C x 21
2R x 12C x 21
2R x 12C x 21
2R x 12C x 21
840*288*840(33.1*11.3*33.1) 840*288*840(33.1*11.3*33.1) 840*288*840(33.1*11.3*33.1) 840*288*840(33.1*11.3*33.1)
950*30*950(37.4*1.2 *37.4) 950*30*950(37.4*1.2 *37.4) 950*30*950(37.4*1.2 *37.4) 950*30*950(37.4*1.2 *37.4)
32(70.4)
32(70.4)
32(70.4)
32(70.4)
5(11)
5(11)
5(11)
5(11)
Long life filter
Long life filter
Long life filter
Long life filter
40 / 38 / 36
42 / 40 / 38
43 / 41 / 39
50 / 47 / 43
6.35 (1/4)
9.52 (3/8)
9.52 (3/8)
9.52 (3/8)
15.88(5/8)
19.05(3/4)
19.05(3/4)
19.05(3/4)
32 / 25
32 / 25
32 / 25
32 / 25
4
4.5
5.5
6.5
Fuse, Thermal protector for fan motor
Thermistor
Thermistor
Thermistor
Thermistor
R-410A
R-410A
R-410A
R-410A
LEV
LEV
LEV
LEV
Single A
Single A
Single A
Single A
4*0.75
4*0.75
4*0.75
4*0.75
Note :
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero.
2. Cooling/heating capacity of indoor unit can be different when it is connected to other type outdoor.
Содержание ABNH366GLAC
Страница 64: ...64 Universal System Air Conditioner II Outdoor Units Introduction 65 AUUW C R410A 67 ...
Страница 72: ...72 Universal System Air Conditioner Inverter SINGLE A AUUW368C AUUW368C1 3 Wiring Diagrams ...
Страница 73: ...Service Manual 73 Inverter SINGLE A AUUW42 48 608C ...
Страница 107: ...Electronic Control Device Service Manual 107 Main P C B ASM A 6871A10209 B 58 Ceiling Cacsette Type ...
Страница 108: ...Electronic Control Device 108 Universal System Air Conditioner BG BR Series Ceiling Duct Type ...
Страница 109: ...Electronic Control Device Service Manual 109 VK VL Series Ceiling Suspended ASM 6871A10025 ASM 6871A10186 ...
Страница 110: ...Electronic Control Device 110 Universal System Air Conditioner Outdoor Unit 1 Component side ...
Страница 111: ...Electronic Control Device Service Manual 111 2 Solder side ...
Страница 113: ...Schematic Diagram Service Manual 113 Ceiling Cassette Type ...
Страница 114: ...Schematic Diagram 114 Universal System Air Conditioner Ceiling Duct Type ...
Страница 115: ...Schematic Diagram Service Manual 115 Ceiling Suspended ...
Страница 116: ...Schematic Diagram 116 Universal System Air Conditioner G G N L N L C 3 C 2 C 4 C 1 Outdoor Unit ...
Страница 154: ...P No MFL30301501 Printed in Korea ...