Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light using igniter

LP gas tank valve is closed

Make sure regulator is securely attached to the LP gas tank per “Installing LP 
Gas Tank,” then turn LP gas tank valve to “OPEN”

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas leak

1 .  Turn LP gas tank valve to “CLOSED”
2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Battery needs to be changed

Replace the “AA” battery (follow assembly step for inserting battery)

Electrode and burners are wet

Wipe dry with cloth

Electrode cracked or broken - sparks at crack

Replacement part(s) may be needed - contact Customer Care at 1-866-439-
9800

Wire loose or disconnected

Reconnect wire or replacement part(s) may be needed - contact Customer Care 
at 1-866-439-9800

Wire is shorting (sparking) between igniter and electrode

Replacement part(s) may be needed - contact Customer Care at 1-866-439-
9800

Thermocouple is not operating correctly

1 .  Disconnect LP Gas tank per “Disconnect LP Gas Tank” section .
2 .  Clean area around thermocouple .
3 .  Connect LP gas tank per “Connect LP Gas Tank” section .
4 .  Relight per “Lighting” section .
5 .  If the outdoor fire pit is still not working, please contact Customer Care at 

1-866-439-9800 for additional assistance .

Bad igniter

Replacement part(s) may be needed - contact Customer Care at 
1-866-439-9800

Burner will not light with match

No gas flow

Check if LP gas tank is empty

a .  If empty, exchange, refill or replace LP gas tank
b .  If LP gas tank is not empty, refer to “Sudden drop in gas flow or 

reduced flame height” (see below)

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas leak

1 .  Turn LP gas tank valve to “CLOSED”
2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Coupling nut and regulator not fully connected

Turn the coupling nut about one-half to three-quarters additional turn until solid 
stop . 

Tighten by hand only - do NOT use tools.

Obstruction of gas flow

1 .  Clear burner/venturi tube
2 .  Check for bent or kinked hose

Disengagement of burner to valve

Re-engage burner and valve

Spider webs or insect nest in burner/venturi tube

Clean burner/venturi tube

Thermocouple is not operating correctly

1 .  Disconnect LP Gas tank per “Disconnect LP Gas Tank” section .
2 .  Clean area around thermocouple .
3 .  Connect LP gas tank per “Connect LP Gas Tank” section .
4 .  Relight per “Lighting” section .
5 .  If the outdoor fire pit is still not working, please contact Customer Care at 

1-866-439-9800 for additional assistance .

Burner ports clogged or blocked

Clean burner ports

Sudden drop in gas flow or reduced flame height

Out of gas

Exchange, refill or replace LP gas tank

Overfilling prevention device may have been activated

1 .  Turn control knob to “  OFF”
2 .  Wait 30 seconds and light outdoor fire pit per “Lighting” section
3 .   If flames are still too low, reset the overfilling prevention device:

a .  Turn control knob(s) “  OFF”
b .  Turn LP gas tank valve to “CLOSED”
c .  Disconnect regulator
d .  Turn control knobs to   (HIGH)
e .  Wait two minutes
f .  Turn control knobs to “  OFF”
g .  Reconnect regulator and leak check connections, being careful not to 

fully open valve

h .  Light outdoor fire pit per “Lighting” section

Irregular flame pattern, flame does not run the 
full length of burner

Burner ports are clogged or blocked

Clean burner ports

Flame is yellow or orange

New burner may have residual manufacturing oils

Burn outdoor fire pit for 15 minutes and reinspect

Spider webs or insect nest in burner/venturi tube

Clean burner/venturi tube

Poor alignment of valve to burner/venturi tube

Ensure burner/venturi tube is properly engaged with valve

Flame goes out

High or gusting winds

Do not use outdoor fire pit in high winds

Low on LP gas

Exchange, refill or replace LP gas tank

Excess flow valve tripped

Refer to “Sudden drop in gas flow or reduced flame height”

Thermocouple is not operating correctly

1 .  Disconnect LP Gas tank per “Disconnect LP Gas Tank” section .
2 .  Clean area around thermocouple .
3 .  Connect LP gas tank per “Connect LP Gas Tank” section .
4 .  Relight per “Lighting” section .
5 .  If the outdoor fire pit is still not working, please contact Customer Care at 

1-866-439-9800 for additional assistance .

Flashback (fire in venturi/burner tube(s))

Burner and/or burner/venturi tube is blocked

Clean burner and/or burner/venturi tube

Flame seems to lose heat when burning in cold 
weather - temperature below 50ºF

Ice has built up on the outside of the LP gas tank 
because the vaporization process is too slow

1 .  Turn off per “Turning Off” section
2 .  Replace with a spare LP gas tank
3 .  Reconnect LP gas tank per “Installing LP Gas Tank” section
4 .  Follow “Checking for Leaks” section
5 .  Light outdoor fire pit per “Lighting” section

If you have any questions or problems, please call our customer service department at 1-866-439-9800, 8 a.m. - 8 p.m., EST, Monday - Friday. 

11 

Need help? 1-866-439-9800, 8 a.m - 8 p.m., EST, Monday - Sunday.

Do not return to place of purchase 

Содержание allen + roth 2592446

Страница 1: ...r WARNING FOR YOUR SAFETY W W If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life W W WHAT TO DO IF YOU SME...

Страница 2: ...0 lb capacity or less Do not use store or transport cylinder where it would be exposed to high temperatures Relief valve may open allowing a large amount of flammable gas to escape When transporting k...

Страница 3: ...liance m Never fill the cylinder beyond 80 percent full n A fire causing serious injury or damage to property may occur if the above is not followed exactly W W Your outdoor fire pit has been checked...

Страница 4: ...g may be required Do NOT operate until all parts have been repaired or replaced W W Use only the regulator and hose assembly provided Use only the replacement regulator and hose assembly specified by...

Страница 5: ...use of any fire glass that is not factory authorized can be dangerous and will void your warranty Hardware Pack 58 23 773 A Screw M5x12 Black Nickel Plated Phillips Head 24 pcs B Screw M5x20 Black Nic...

Страница 6: ...tion instructions on how to make the solution are included in the Operating Instructions section of this manual 1 Precision filled LP gas grill tank with Acme Type 1 external threaded valve connection...

Страница 7: ...rized can be dangerous and will void your warranty W W CAUTION Do NOT cover pilot housing Note Fire glass should be 0 8 2 0 in 2 5 cm long Approx 8 8 lb 4 kg of fire glass is needed 7 Place Table Inse...

Страница 8: ...ing LP Gas Tank 1 Make sure the control knob is in the OFF position Figure 3 2 Before disconnecting make sure the LP gas tank valve is CLOSED 3 Disconnect regulator hose assembly from LP gas tank by t...

Страница 9: ...ontrol knob in for 20 seconds to heat the thermocouple a safety device that stops the gas flow when a firepit is not lit Holding the knob in for 20 seconds warms it up so the gas flow will continue 4...

Страница 10: ...nsequential damages or limitations on how long a warranty lasts so the above exclusion and limitations may not apply to everyone We do not authorize any person or company to assume for it any other ob...

Страница 11: ...section 4 Relight per Lighting section 5 If the outdoor fire pit is still not working please contact Customer Care at 1 866 439 9800 for additional assistance Burner ports clogged or blocked Clean bu...

Страница 12: ...12 Gas Fire Pit Model No GAD17102L...

Страница 13: ...CENDIO O EXPLOSI N Si percibe olor a gas Cierre el suministro de gas hacia el artefacto Apague cualquier llama expuesta Si el olor permanece ret rese del rea de inmediato Despu s de salir del rea llam...

Страница 14: ...a de presi n puede abrirse y dejar escapar una gran cantidad de gas inflamable Cuando lo transporte mantenga el cilindro asegurado en una posici n vertical con la v lvula del cilindro cerrada CUANDO L...

Страница 15: ...de abrir la v lvula de descarga y producir un escape de gas k Coloque la tapa antipolvo en la salida de la v lvula del cilindro cuando no est en uso Solo instale el tipo de tapa antipolvo que se propo...

Страница 16: ...era antes de cada uso del artefacto Si hay evidencia de abrasi n desgaste cortes o fugas debe reemplazar la manguera antes de utilizar el artefacto W W Un t cnico calificado debe inspeccionar este fog...

Страница 17: ...4 513 7 Repisa 58 24 514 8 Pata posterior izquierda 58 24 515 9 Pata posterior derecha 58 24 516 10 Panel lateral 2 58 24 517 11 Base 58 23 761 12 Pie 4 58 23 762 13 Pata izquierda frontal 58 24 518 1...

Страница 18: ...a paso en el orden presentado Para terminar el armado de la unidad necesitar 1 Soluci n para detecci n de fugas las instrucciones acerca de c mo elaborar la soluci n est n incluidas en la secci n Inst...

Страница 19: ...garant a W W PRECAUCI N NO cubra la carcasa del piloto Nota Las rocas de vidrio para fuego deben tener entre 0 8 pulg y 2 pulg entre 2 cm y 5 cm de largo Se necesitan aproximadamente 8 8 lb 4 kg de r...

Страница 20: ...tran en el manual del propietario para encender el fog n 3 Encienda el fog n a la temperatura m s alta 4 Deje que las rocas de lava se calienten a temperatura m xima durante 30 minutos antes de disfru...

Страница 21: ...ue las conexiones de la v lvula y de la manguera del regulador est n bien fijadas al quemador y al tanque 2 Revise visualmente la conexi n entre el tubo Venturi del quemador venturi y el orificio 3 As...

Страница 22: ...1 2 3 4 Revise las llamas del quemador para asegurarse de que el fog n para exteriores funcione de manera adecuada Figura 5 5 Consulte las instrucciones de limpieza adecuadas a continuaci n 6 Revise...

Страница 23: ...fallas bajo un uso y servicio normales y que determinemos en nuestra propia opini n que presentan fallas despu s de examinarlas Antes de devolver cualquier pieza debe ponerse en contacto con nuestro...

Страница 24: ...loqueados Limpie el quemador o el tubo Venturi del quemador La llama parece perder calor cuando el tiempo es fr o temperatura por debajo de los 50 F 10 C Se ha acumulado hielo en la parte exterior del...

Отзывы: