Maintenance
43
GA03108_002_C1 - 04/2018 - © Leybold
5.4 Cleaning the Intake Screen
Observe all safety information provided in Sections 0.3 to 0.5 and 5.1.
An intake screen is located in the intake port to collect foreign objects. It
should be kept clean in order to avoid a reduction of the pumping speed.
To do so, take off the intake line. Remove the intake screen from the intake
flange and rinse it using a suitable solvent. Then thoroughly dry it with com-
pressed air. If the intake screen is damaged, replace it.
5.5 Cleaning the Pumping Chamber
Observe all safety information provided in Sections 0.1 to 0.3 and 5.1.
Under dirty operating conditions, contaminants may be deposited in the
pumping chamber or on the impellers. After removing the two connecting
lines, the contaminants can be blown out with dry compressed air or flushed
out with a suitable solvent.
Contaminants that cannot be blown or flushed out, can be removed com-
pletely from the pumping chamber with a wire brush, metallic sponge or
scraper.
Then change the lubricant.
During cleaning, the blower must be turned only by hand.
Please make sure that the impellers are turned in a way that fingers or
hands can not be trapped between the impellers or between impellers and
housing. Due to the high mass and inertia of the impellers serious injuries
can occur even if the impellers are turned by hand only.
The loosened deposits must not remain in the pump. After cleaning, check
the pump by slowly turning the impellers by hand. They should move freely
and without any resistance.
Generally, the Roots pump does not need to be disassembled. If necessa-
ry, this should only be done by our after-sales service.
CAUTION
CAUTION
CAUTION
NOTICE