Description
18
GA03108_002_C1 - 04/2018 - © Leybold
The motor overload protection switch must be set to the nominal current
stated in the table in each case. The separate fan current may only be
operated within the permissible voltage range (230 V, 50 Hz and 265 V, 60
Hz) as otherwise the fan will be damaged, especially so when using a fre-
quency converter. In the case of deviating voltages you must use a trans-
former.
NOTICE
1.3.1 Voltage ranges for the canned motors
Nominal power / Nominal current at Nominal power / Nominal current at
50 Hz
60 Hz
Pump model
200 V
230 V
400 V
200-208 V
265 V
460 V
kW A kW A
kW A
kW A kW A kW A
WS/WSU 251
0.9 4.8 1.1 5.5
1.1 3.2
0.9 4.8 1,4 5,5 1.4 3.2
WS/WSU 501
1.6 7.8 2.2 9
2.2 5.2
1.6
7.8 2.4 10 2.4 5.8
WS/WSU 1001
3 13
4 15.7
4 9.1
3 13 4.4 14.7 4.4 8,5
WS/WSU 2001
5 21 7.5 26
7.5 15
5 21 8.5 26 8.5 15