User Guide
Page 12 of 62
Leviton MLC 16D Motorized Lighting Controller
62
•
X-axis and Y-axis.
Assigns a trait to the X or Y-axis of the joystick. More than
one trait of a fixture can be assigned to either axis and a single trait can be
assigned to both axes. X is usually horizontal or pan; Y is usually vertical or tilt.
•
B/O (Blackout).
Sets the trait to the assigned Blackout value whenever the
Blackout
button is pressed.
•
BoValue (Blackout Value).
Assigns the value a trait is at when the
Blackout
button is pressed.
•
Master.
Assigns a trait to the Grand Master control.
•
Default.
Assigns a default value to a trait; pressing the
Default
button causes
the default value to be applied whenever a fixture is active.
•
Max and Min.
Assigns maximum and minimum values to a continuous trait.
This is useful when a device does not use the full range of DMX512 values, or
when a continuous trait is part of a union.
Adjusting Indexed Trait Parameters
Indexed traits are made of index values, which can be changed at any time. Each
index can be assigned a specific label just as each trait can be assigned a specific
label.
You can modify the following parameters for indexed traits.
•
Channel.
Determines which channel of the DMX512 stream should be used for
this trait. This is a relative number that is added on to the base address of the
fixture once it is assigned to a
Fixture Select
button.
•
X-axis and Y-axis.
Assigns a trait to the X or Y-axis of the joystick. More than
one trait of a fixture can be assigned to either axis and a single trait can be
assigned to both axes. X is usually horizontal or pan; Y is usually vertical or tilt.
•
B/O (Blackout).
Sets the trait to the assigned Blackout value whenever the
Blackout
button is pressed.
•
BoValue (Blackout Value).
Assigns the value a trait is at when the
Blackout
button is pressed.
•
Default.
Assigns a default value to a trait; pressing the
Default
button causes
the default value to be applied whenever a fixture is active.
•
Indexes (Number of Indexes).
Specifies the number of indexes used by the
trait. There are a maximum of 255 indexed values that can be assigned.
•
IL1-ILX (Index Label 1-X).
Assigns a label to the specified index value. Index
labels are stored separately from the Table of Trait Labels, providing up to 896
labels to choose from or create.
•
IV1-IVX (Index Value 1-X).
Assigns a value to the specified index value.
Adjusting Union Trait Parameters
Union traits act as a header for continuous and indexed traits grouped together
on the same channel. The end of the group is marked by an end union trait. This
trait is automatically inserted when you select and insert a union trait.
You can modify the following parameters for union traits.
•
Channel.
Determines which channel of the DMX512 stream should be used for
this trait. This is a relative number that is added on to the base address of the
fixture once it is assigned to a
Fixture Select
button.
•
B/O (Blackout).
Sets the trait to the assigned Blackout value whenever the
Blackout
button is pressed.
Содержание MLC16
Страница 2: ......
Страница 6: ...User Guide iv Leviton MLC 16D Motorized Lighting Controller iv ...
Страница 68: ...User Guide Page 62 of 62 Leviton MLC 16D Motorized Lighting Controller 62 ...
Страница 69: ......