Online commands
Leuze electronic GmbH + Co. KG
BCL 92
50
Acknowledge parameter message
Command
’PS’
Description
The command acknowledges the received message and delivers an acknowl-
edgment status which indicates whether the message was valid or invalid.
Parameter
’PSx’
x
Status
’0’
Valid transfer
’1’
Invalid message
’2’
Invalid message length
’3’
Invalid block check type
’4’
Invalid block check checksum
’5’
Invalid data length
’6’
Invalid message data
’7’
Invalid start address
’8’
Invalid parameter set
’9’
Invalid parameter type
Transfer parameters
Command
’PT’
Description
The command transmits parameter data starting from the defined address and
stores them in an intermediate buffer.
If the status indicates that further messages follow, these are also stored in the
intermediate buffer before they are then stored under the corresponding pa-
rameter set type in the EEPROM.
The transmission can optionally occur with a block check test of the message
data.
Parameter
<BCC type> <PS type> <Status> <Start address> <Para0L> <Para0H>
[… <Para122L>][<BCC>]
Acknowledgment
’PSx’
x
Status
’0’
Valid transfer
’1’
Invalid message
’2’
Invalid message length
’3’
Invalid block check type
’4’
Invalid block check checksum
’5’
Invalid data length
’6’
Invalid message data
’7’
Invalid start address
’8’
Invalid parameter set
’9’
Invalid parameter type
Example
’PT03203305’
Address 33 (equal scans) is set to 5. Save in RAM with reset (immediate ac-
ceptance of the change and temporary storage)