Manual definition of the reference code
Command
’RS’
Description
This command can be used to define a new reference code in the device by
means of direct input via the serial interface. The data is saved in the parame-
ter set according to your input under reference code 1 or 2 and stored in the
working buffer for direct further processing.
Parameter
’RSyvxxzzzzzzzz’
y, v, x and z are placeholders (variables) for the actual input.
y
Def. reference code no.
’1’
(code 1)
’2’
(code 2)
v
Storage location for reference code:
’0’
RAM+EEPROM
’3’
RAM only
xx
Def. code type (see command ’CA’)
z
Def. code information (1 … 30 characters)
Acknowledgment
’RSx’
x
Status
’0’
Invalid Rx command
’1’
Invalid command
’2’
Insufficient memory for reference code
’3’
Reference code has not been saved
’4’
Reference code invalid
Example
Entry = ’RS130678654331’
• Code 1 (1)
• RAM only (3)
• UPC (06)
• Code information