Online commands
Leuze electronic GmbH + Co. KG
BCL 92
45
Teach-in
Command
’RT’
Description
This command enables a reference code to be defined quickly by reading an
example label.
Parameter
’RTy’
y
Function
’1’
Defines reference code 1
’2’
Defines reference code 2
’+’
Activates the definition of reference code 1 or 2
’-’
Ends the teach event
Acknowledgment
The device first responds with the command ’RS’ and corresponding status
(see command ’RS’). After a bar code has been read, it sends the result in the
following format:
’RCyvxxzzzzz’
y, v, x and z are placeholders (variables) for the actual input.
y
Def. reference code no.
’1’
(code 1)
’2’
(code 2)
v
Storage location for reference code:
’0’
RAM+EEPROM
’3’
RAM only
xx
Def. code type (see command ’CA’)
z
Def. code information (1 … 30 characters)
NOTICE
With this function, only code types are recognized that are identified using the
’autoConfig’
func-
tion or which were set in the set-up.
Ä
After each reading via an
’RTy’
command, explicitly switch off the function again since failure to do so
will interfere with other commands as well as prevent execution of a new
’RTy’
command.