Starting up the device
Leuze electronic GmbH + Co. KG
ELC 100
27
7
Starting up the device
WARNING
Improper use of the safety sensor may result in serious injury!
Ä
Make certain that the entire device and the integration of the optoelectronic protective de-
vice were inspected by qualified and instructed persons (Necessary competencies).
Ä
Make certain that a dangerous process can only be started while the safety sensor is
switched on.
Prerequisites:
• Safety sensor mounted (see chapter 5 "Mounting") and connected (see chapter 6 "Electrical connec-
• Operating personnel were instructed in proper use
• Dangerous process is switched off, outputs of the safety sensor are disconnected, and the system is
protected against being switched back on
Ä
After start-up, check the function of the safety sensor (see chapter 8.1 "Before commissioning and fol-
lowing modifications").
7.1
Switching on
Requirements for the supply voltage (power supply unit):
• Safe mains separation is ensured.
• Current reserve of at least 2 A is available.
Ä
Switch on the safety sensor.
ð
The safety sensor performs a self test.
Check operational readiness of sensor
Ä
ð
The safety sensor is ready for use.