Description ODSL 30
30
ODSL 30
Leuze electronic
3.6
Operation ODSL 30
Indicator and operating elements
Figure 3.10:Indicator and operating elements ODSL 30
3.6.1
LED indicators ODSL 30
Notice
The 3 yellow LEDs Q1, Q2 and Q3 for the status display of the up to 3 switching outputs are
additionally located in the optical window of the ODSL 30. Only the LEDs for those switching
outputs that are actually available in the respective device version have a function.
PON
Q1
Q2
Q3
Leuze
electronic
ENTER
Device LEDs
Two-line LC display with 16 characters each
Keypad with 3 buttons
Leuze electronic
Dist. [mm]
10687
LED
Color
Display when
Sensor operation
activated teach-in
characteristic output
curve
1)
1)
The teach-in process is described in detail in section 3.4.1 and section 6.3
PON
green, continuous
light
ready
teach event
green, flashing
–
teach event
green off
no voltage
Q1,
Q2,
Q3
yellow, continuous
light
object inside teach-in measurement
distance
teach event
yellow flashing
–
teach event
yellow off
object outside teach-in measure-
ment distance or no signal present