Description ODSL 30
Leuze electronic
ODSL 30
35
TNT
35/7-2
4
V
Output Q Menu
Q1 Function sel.
Q1 Upper Sw. Pt.
Value:
001000
Q1 Upper Sw. Pt.
act Value:
001000
Upper switching point of out-
put Q1 in millimetres
1000
Q1 Lower Sw. Pt.
Value:
000199
Q1 Lower Sw. Pt.
act Value:
000199
Lower switching point of out-
put Q1 in millimetres
199
Q1 Hysteresis
Value:
000020
Q1 Hysteresis
act Value:
00020
Switching hysteresis of output
Q1 in millimeters
20
Q1 light/dark
light switching
Q1 light/dark
light switching
Q1 is active if an object is in
the switching range
X
Q1 light/dark
dark switching
Q1 is active if no object is
present in the switching range
Q1 Driver
PNP high active
Q1 Driver
PNP high active
Q1 is high-side output (PNP)
X
Q1 Driver
NPN low active
Q1 is low-side output (NPN)
Q1 Driver
PNP/NPN pushpull
Q1 is push-pull output
Return
Return to level 2
Return
Return to level 1
Analogue Out
Menu
Cal. Ana. Output
Current 4-20mA
Cal. Ana. Output
Current 4-20mA
Current output calibrated,
Voltage output uncalibrated
X
Cal. Ana. Output
Voltage 1-10V
Voltage output calibrated,
Current output uncalibrated
Pos for max. val
Value:
005000
Pos for max. val
act Value:
05000
Distance [mm], at which the
max. analogue value is output
5000
Pos for min. val
Value:
000200
Pos for min. val
act Value:
00200
Distance [mm], at which the
min. analogue value is output
200
Return
Return to level 1
Service Menu
Password Check
inactive
Password Check
inactive
Password for menu access not
active
X
Password Check
activated
Menu access password active,
password: 165 (n. changeable)
ODSL 30 Serial No
Val:
99999
Display of serial number, no
changes possible
SW V01.20 YYMMDD
Val:
31024
Display of software version, no
changes possible
Parameter YYMMDD
Val:
31024
Display of parameter version,
no changes possible
Interface-Type
Analogue Inter-
face
Display of the interface type,
no changes possible
Return
Return to level 1
Exit from Menu
Return to measurement mode
Level 1
Level 2
Level 3
Level 4
Explanation / Notes
Default