Software
Leuze electronic
ODSL 30
65
TNT
35/7-2
4
V
7
Software
General description
The ODS 96 configuration software can be used with a connected ODSL 30 to display
measurement values.
The software is available via download from
www.leuze.de
.
Notice
In connection with the ODSL 30, the ODS 96 configuration software can only be used
for the display of measurement values, but not for the configuration of the device. For
this purpose, the left arrow key (up arrow) on the keypad must be pressed while the
device is switched on. After that, the ODSL 30 is in PC configuration mode.
7.1
Connecting to a PC
7.1.1
Connection of the ODSL 30 to a PC
The ODSL 30 is connected to a PC via the programming terminal UPG 5. The terminal is
simply inserted between the ODSL 30 and the connection cable. The UPG 5 is connected
to the PC via the serial interface cable that ships with the UPG 5.
Figure 7.1: Connection of the ODSL 30 to a PC via the programming terminal UPG 5
Notice
The measurement values of the ODSL 30 can visualized on the PC using the ODS 96
configuration software. However, a configuration of the device via the ODS 96 config-
uration software is not possible. Visualization of the measurement values is only pos-
sible up to 15m!
ODSL 30
UPG 5
To the PC
Connection cable