![Leuze electronic LSIS 472i M45-I1 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019023.webp)
Electrical connection
Leuze electronic
LSIS 472i
23
7.3
BUS OUT (RS 232 and switching outputs IO5 … IO8)
8-pin M12 socket (A-coded)
Figure 7.3: Pin assignment of the BUS OUT connection
Table 7.2:
BUS OUT pin assignment
Connection cables: see table 14.2
NOTICE
Maximum input current
The maximum input current of the switching inputs is 8 mA.
FE
5
7
6
1
8
2
3
4
Pin
Designation
Assignment
1
IO5
Configurable switching output 1
Compartment fine positioning (-X)
2
IO6
Configurable switching output 2
Compartment fine positioning (+X)
3
GND
Negative supply voltage 0 VDC
4
IO7
Configurable switching output 3
Compartment fine positioning (+Y)
5
IO8
Configurable switching output 4
Compartment fine positioning (-Y)
6
Rx
Rx signal (RS 232)
7
Tx
Tx signal (RS 232)
8
FE
Functional earth
(Thread for M12
connector plug)
FE
Connection cable shield
The shield of the connection cable is on the thread of
the M12 connector plug.
The thread of the M12 connector plug is part of the
metallic housing. The housing is at the potential of
the functional earth via pin 8.
NOTICE
Maximum loading of the switching outputs
Do not load the switching outputs with more than 60 mA at +18 … +30 VDC.
The switching outputs are protected against short-circuit, overcurrent, overvoltage, excess tempera
-
ture and transients.
NOTICE
Maximum cable length 10 m
Operation of the RS 232 interface is only permissible with shielded cables with maximum cable length
of 10 m.