![Leuze electronic LSIS 472i M45-I1 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019010.webp)
Device description
Leuze electronic
LSIS 472i
10
• Optionally via MA 2xxi modular connection unit
• Interfaces:
• RS 232 and Ethernet TCP/IP
• PROFINET, PROFIBUS, CANopen, DeviceNet and EtherCat via MA 2xxi modular connection unit
• Alignment via display and webConfig tool
• Diagnostics in Process mode through image transfer via FTP transfer
• Optional model with heating for use to
-
35 °C
3.1.3 Accessories
Special accessories are available for the smart camera. The accessories are optimally matched to the
smart camera:
• Ready-made connection and interconnection cables for M12 connectors
• Mounting devices for precise mounting
• Reflectors for
Rack Near
and
Rack Far
compartment depths
3.1.4 Device model with heating
The device is optionally available as a model with integrated heating. In this case, heating is permanently
installed ex works.
The heating consists of two parts:
• Optics glass heating
• Housing heater
Features of the integrated heating:
• Extends the application range to -35 °C
• Supply voltage: 24 VDC ± 20 %
• Required conductor cross-section for the power supply: At least 0.75 mm
2
Thus, it is not possible to use ready-made cables.
3.2
Connection technology
The device is connected using variously coded M12 connectors.
1
SERVICE: host and service interface (Ethernet); M12 socket (D-coded)
2
PWR: supply voltage (18 V … 30 VDC), IO1 … IO4; M12 plug (A-coded)
3
BUS OUT: RS 232 interface, IO5 … IO8; M12 socket (A-coded)
Figure 3.2: Electrical connections
3
2
1