![Leuze electronic LSIS 472i M45-I1 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019012.webp)
Device description
Leuze electronic
LSIS 472i
12
3.3.1 LED indicators
Table 3.1:
Meaning of the LED indicators
3.3.2 Control buttons
The display is controlled via the control buttons. You can call up various pieces of information via the
control buttons (e.g., the IP address of the device) or make adjustments in the application; e.g., teach-in.
•
- Scrolling through functions (upwards)
•
- Scrolling through functions (downwards)
•
– Escape button: exit the menu item, move up one menu level
•
– Enter button: select function, confirm/enter value
Navigating within the menus
Use the navigation buttons
to move through the menu.
Activate the desired selection with the enter button
.
Press the escape button
to move up one menu level.
Selecting options
Set the desired option with the navigation buttons
and the enter button
.
3.3.3 Display
Display functions
The following functions can be displayed and activated in the display:
• Device information
LED
Color, state
Description
LED
PWR
Off
Device is switched off
• no supply voltage
Green, flashing
Device is being initialized
• Supply voltage connected
• Self test running
• Initialization running
Green, continuous light Process mode
• Initialization finished
• Self test successfully finished
• Position display activated
Orange, continuous
light
Service mode
• Alignment via display
• Configuration via Ethernet service interface
• Configuration via the webConfig tool
Red, flashing
Warning set
• Inspection mode
• Temporary operating fault
Red, continuous light
Device error
LED
BUS
Off
No supply voltage
Green, flashing
Bus initialization, a pulse
Green, continuous light Device ready for communication
Red, flashing
Communication error
ESC
ESC