2011/04
Resetting the IT 1900 to factory settings
To reset all parameters to factory settings, scan the adjacent
barcode.
Attention!
All settings are lost!!!
Trigger
To activate the read process, a trigger signal is to be sent via the serial RS 232 interface or USB interface (COM port emulation
only). The command is to be sent at the set baud rate, parity, and data and stop bits.
The command for activation is:
SYN T CR
ASCII decimal values: 022; 084; 013
To cancel read readiness, send a deactivation.
The command for deactivation is:
SYN U CR
ASCII decimal values: 022; 085; 013
Following a successful read operation, the IT 1900 deactivates itself.
The second option is activation via the built-in trigger button.
Configuration for the Leuze standard protocol
Scan the adjacent 2D code.
The IT 1900 is set to the following transmission parameters:
RS 232 transmission with 9,600 baud, 8 data bits, 1 stop bit, no parity,
prefix <STX>, terminators <CR><LF>.
IT 1900