Leuze electronic GmbH + Co. KG
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
[email protected] • www.leuze.com
Connecting the IT 1900 to the MA 2xx
i
required parts:
1x
IT 1900g XX-2
1x
50114517 KB 232-1 IT190x
1x
50113397
KB JST-HS-300
1x
MA 2xxi
for the respective fieldbus system
Procedure:
1.
Connect the KB JST-HS-300 cable to the system connectors in the MA 2xx
i
.
2.
Connect the interface cable to cable KB JST-HS-300.
3.
Scan the adjacent 2D code. The IT 1900 is set to the following transmission parameters:
RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, terminators
<CR><LF>.
Connecting the IT 1900 to the PS/2 interface
The operation of the IT 1900 in keyboard emulation mode is described in this section. A PC keyboard is emulated in this operating
mode. The data which are read in are written directly to the currently activated program. Thus, the data can be processed further
in all standard programs.
required parts:
1x
IT
1900g
XX-2
1x
50114519
KB PS2-1 IT190x
Procedure:
1.
Switch off the PC.
2.
Disconnect the keyboard.
3.
Plug in the IT 1900 hand-held scanner between the
keyboard and the PC.
4.
Switch the PC back on.
5.
Scan the 2D code shown below.
Disconnect