background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

IT 1900 - 01

[email protected]  •  www.leuze.com

Connecting the IT 1900 to the serial PC interface

With voltage supply via PIN 9 for RS232 cable (part. no. 50114517)

required parts:

1x

IT 1900g XX-2

1x 

50114517 KB 232-1 IT190x

With voltage supply via power supply unit with cable RS232 (part no. 50114517)

required parts:

1x

IT 1900g XX-2

1x 

50114517 KB 232-1 IT190x

1x

50114525

Power supply unit

Notice!

 

The 

KB 232-1 IT190x

 cable (part. no. 50114517) uses TTL level (0V…5V) for data transmission. Alternatively, the 

KB 232-2 IT190x

 cable (part. no. 50115105) can be used which works with the regular RS232 level (-12V…+12V) and 

therefore features a higher interference rejection. Both cables are connection compatible.

Procedure:

1.

Switch off the PC.

2.

Connect the interface cable to a free COM port (RS 232) on the computer, to the IT 1900 as well as to the power supply unit (if 
present).

3.

Switch the PC back on.

4.

Scan the adjacent barcode. 
The IT 1900 is set to the following transmission parame-
ters: 
RS 232 transmission with 115,200 baud, 8 data bits, 1 
stop bit, no parity, terminators <CR><LF>.

5.

If necessary, adjust the transmission parameters of the 
used COM port to those of the IT 1900.

Attention!

 

We recommend connecting the IT 1900 directly to a PC or to the MA 21 or MA 41… connector units. If connecting to 
other components, please note that the voltage level range is maintained on the data lines!

IT 1900

2D-code hand-held scanner

Содержание IT 1900

Страница 1: ...2 cable part no 50114517 z PS 2 cable part no 50114519 z USB cable 3m part no 50114521 z USB helix cable 5m part no 50114523 z Power supply unit part no 50114525 Dimensioned drawing A Cable entry depending on the cable max Ø 20mm cable Ø 5mm Electrical connection for RS 232 cable for USB cable for PS 2 cable 9 pin Sub D Signal Connection for power supply unit IT 1900 RJ41 2 TXD 4 3 RXD 5 5 GND ext...

Страница 2: ...13 Mil 0 330 mm 20 Mil 0 508 mm 6 7 Mil 0 170 mm 10 Mil 0 254 mm 20 Mil 0 508 mm Code 39 0 200 400 600 100 300 500 700 5 Mil 0 127 mm Code 39 PDF 417 Data Matrix QR Code UPC 13 Mil 0 330 mm 20 Mil 0 508 mm 6 7 Mil 0 170 mm 10 Mil 0 254 mm 20 Mil 0 508 mm Code 39 IT 1900g HD 2 IT 1900g SR 2 Typ read distance 1 mm 0 200 400 600 100 300 500 700 5 Mil 0 127 mm Code 39 PDF 417 Data Matrix QR Code UPC 1...

Страница 3: ...m the computer 4 Check the operational readiness of the scanner by pointing the scanning sur face towards a flat surface and pulling the trigger A red target line as well as the red illumination should now be visible Now scan a sample label The scanner emits an audible signal to confirm that the label has been read if necessary the data are now passed on to the computer Configuration The hand held...

Страница 4: ... stop bits The command for activation is SYN T CR ASCII decimal values 022 084 013 To cancel read readiness send a deactivation The command for deactivation is SYN U CR ASCII decimal values 022 085 013 Following a successful read operation the IT 1900 deactivates itself The second option is activation via the built in trigger button Configuration for the Leuze standard protocol Scan the adjacent 2...

Страница 5: ...th the regular RS232 level 12V 12V and therefore features a higher interference rejection Both cables are connection compatible Procedure 1 Switch off the PC 2 Connect the interface cable to a free COM port RS 232 on the computer to the IT 1900 as well as to the power supply unit if present 3 Switch the PC back on 4 Scan the adjacent barcode The IT 1900 is set to the following transmission parame ...

Страница 6: ...acent 2D code The IT 1900 is set to the following transmission parameters RS 232 transmission with 9600 baud 8 data bits 1 stop bit no parity terminators CR LF Connecting the IT 1900 to the MA 21 required parts 1x IT 1900g XX 2 1x 50114517 KB 232 1 IT190x 1x 50035421 KB 021 Z 1x 50030481 MA 21 100 Pin assignments KB021 Z Core colour signal terminal in the MA 21 brown RXD 26 white TXD 27 blue GND 2...

Страница 7: ...meters RS 232 transmission with 9600 baud 8 data bits 1 stop bit no parity terminators CR LF Connecting the IT 1900 to the PS 2 interface The operation of the IT 1900 in keyboard emulation mode is described in this section A PC keyboard is emulated in this operating mode The data which are read in are written directly to the currently activated program Thus the data can be processed further in all...

Страница 8: ...ation of the IT 1900 as a serial interface on a USB port is described in this chapter A COM interface is emulated in this operating mode The data which are read in are sent to a new COM interface The driver with which you emulate this COM inter face can be downloaded from our homepage at www leuze de Thus the data can be processed further in programs which expect data via COM interfaces required p...

Отзывы: