Mounting
Leuze electronic
DDLS 508
27
Detach the contour of the optical window from the drilling template along the perforation (see figure 4.2).
Affix the removed drilling template to the optical window of the mobile device using the supplied self-
adhesive labels.
Switch on the alignment laser of the stationary device.
Activate the LAS (Alignment laser) operating mode to switch on the alignment laser (see chapter 6.1).
Move the mobile device on the lifting axis in manual operation to maximum distance.
Align the stationary device using the alignment screws (see figure 3.1, point 11 and point 12) and, if
necessary, using the C profile rails.
The target spot of the alignment laser must be in the center of the drilling template on the mobile device.
Move the mobile device on the lifting axis in manual operation to minimum distance.
The target spot of the alignment laser must not extend beyond the outer ring of the drilling template on
the mobile device.
If necessary, realign the stationary device.
Switch off the alignment laser of the stationary device.
Activate the AUT (Automatic) operating mode to switch off the alignment laser (see chapter 6.1).
Affix the detached drilling template to the optical window of the stationary device using the supplied self-
adhesive labels.
Switch on the alignment laser of the mobile device.
Activate the LAS (Alignment laser) operating mode to switch on the alignment laser (see chapter 6.1).
Move the mobile device on the lifting axis in manual operation to maximum distance.
Align the mobile device using the alignment screws (see figure 3.1, point 11 and point 12) and, if neces
-
sary, using the C-profile rails.
The target spot of the alignment laser must be in the center of the drilling template on the stationary
device.
Move the mobile device on the lifting axis in manual operation to minimum distance.
The target spot of the alignment laser must not extend beyond the outer ring of the drilling template on
the stationary device.
If necessary, realign the mobile device.
Switch off the alignment laser of the mobile device.
Activate the AUT (Automatic) operating mode to switch off the alignment laser (see chapter 6.1).
Remove the drilling template from the stationary device.
This concludes the mounting of the devices in the lifting axis.
Further procedure:
• Perform the fine adjustment for the lifting axis (see chapter 6.2 "Fine adjustment").
4.3
Mounting without alignment laser
Observe the mounting instructions (see chapter 4.1 "Mounting instructions").
4.3.1 Horizontal mounting (travel axis) without alignment laser
Depending on mechanical conditions, mount the stationary or mobile device with four M5 screws via the
fastening holes in the mounting plate.
Move the mobile device as close as possible to the stationary device.
You will achieve greater flexibility during basic installation if you mount the devices on C profile
rails.
You will achieve greater flexibility during basic installation if you mount the devices on C profile
rails.