Mounting
Leuze electronic
DDLS 508
26
Switch off the alignment laser of the second device.
Activate the AUT (Automatic) operating mode to switch off the alignment laser (see chapter 6.1).
Remove the drilling template from the device that was mounted first.
This concludes the mounting of the devices in the travel axis.
Further procedure:
• Perform the fine adjustment for the travel axis (see chapter 6.2 "Fine adjustment").
4.2.2 Vertical mounting (lifting axis) with the alignment laser
Mount the two devices opposite one another with a lateral offset of 30 mm.
Mount the devices so that the center of the transmitter of one device is opposite the center of the recei
-
ver of the other device.
1
Lateral offset 30 mm
Figure 4.8: Lateral offset of the devices with vertical mounting
NOTICE
Do not change the mounting position of the device that was mounted first!
When aligning the second device, note that the mounting position of the device that was mounted first
must not be changed.
NOTICE
Vertical mounting only with the target spot of the alignment laser!
For the vertical mounting of the devices, only the target spot of the alignment laser is used (see
figure 4.4).
The level and laser spots 1 … 4 cannot be used.
30 mm