Mounting
Leuze electronic
DDLS 508
24
1
Laser spot 1
2
Laser spot 2
3
Laser spot 3
4
Laser spot 4
5
Alignment laser
6
Target spot
7
Reference edge
8
Alignment screw for horizontal alignment
X
Distance of laser spots to the reference edge
Figure 4.5: Horizontal alignment of the target spot
Turn the alignment screw (8) until at least two laser spots (1 - 4) are the same distance (X) to the guide
rail or to a reference edge (7) that is parallel to the guide rail.
If possible, use laser spot 1 and laser spot 3 for alignment.
Set the distances of the laser spots to the reference edge exactly to 1 mm.
Figure 4.6: Measure distance from laser spot to reference edge
Vertical alignment
Adjust the vertical setting of the device using the alignment screw (2) at the upper left.
Turn the alignment screw until the air bubble in the level is centered between the limit marks.
7
x
x
x
x
8
5
6
1
2
3
4
65
63
64
66
67
68
69
71
72
70