Configuration control
Leuze electronic
DCR 55
49
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Cellphone Enable
CD OP
S/P/R/
G
CE
0
0
Disable Cellphone reading mode
1
Enable Cellphone reading mode
Upload Images
CD OP
S/P/R/
G
DI
0
0
Disable uploading images
Example:
CDOPPDI0
1
Enable uploading
Example:
CDOPPDI1
When Upload Images is set, each im-
age captured by the reader will be sent
as a stream of data to the host
Decode Trigger Mode
CD OP
S/P/R/
G
MD 0
0
Trigger Mode (default)
Example:
CDOPSMD0
1
Motion Detection Mode
Example:
CDOPSMD1
2
Continuous scan Mode
Example:
CDOPSMD2
Notes: TBD
Target Tolerance (percent)
CD VA
S/P/R/
G
TT
1600
For reader to accept a barcode, it must
be within certain distance from the cen-
ter of the image. The distance is defined
as a percentage of the barcode’s
smaller dimension. For example, with a
10 x 20 mm barcode and a setting of
150 (%), the barcode must be within 15
mm of the center of the image.
Any value over 1000 is considered infi-
nite tolerance, and no target checking is
performed.
Valid Range: 1 to 1000
Example
: CDVASTT1600
Duplicate Block Time (ms)
CD VA
S/P/R/
G
BT
0
Consecutive duplicate barcodes (i.e.
barcodes that contain the same data)
are blocked for this amount of time (in
milliseconds). 0 turns off blocking of du-
plicate barcodes.
Valid Range: 0 to xx
Example
: CDVASBT100
Block Duplicates
CD VA
S/P/R/
G
BD
0
0
Disable – do not block dupli-
cates
Example
: CDVASBD0
1
Enable –block duplicates for the
amount of time set in DC-
VAGBT
Example
: CDVASBD1
If enabled, the reader will not output the
same barcode until the barcode has not
been seen for the “duplicate block time”
period.