Configuration control
Leuze electronic
DCR 55
29
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Codabar
SY
CBA
R
S/P/R/
G
EN
1
0
Disable
Example:
SYCBARSEN0
1
Enable
Example: SYCBARSEN1
Codabar – Require
Checksum
SY
CBA
R
S/P/R/
G
CS
0
0
Disable checksum check and out-
put checksum if one exists.
Example:
SYCBARSCS0
1
Enable checksum check and out-
put checksum.
Example:
SYCBARSCS1
2
Enable checksum check and strip
checksum.
Example:
SYCBARSCS2
Note:
This setting value is ignored if Cod-
abar decoding is disabled.
Codabar – Strip Start/
Stop Characters
SY
CBA
R
S/P/R/
G
SS
0
0
Disable
Example:
SYCBARSSS0
1
Enable
Example:
SYCBARSSS1
Note:
This setting value is ignored if Cod-
abar decoding is disabled
Codablock A
SY
COD
A
S/P/R/
G
EN
0
0
Disable
Example:
SYCODASEN0
1
Enable
Example:
SYCODASEN1
Codablock F
SY
COD
F
S/P/R/
G
EN
0
0
Disable
Example:
SYCODFSEN0
1
Enable
Example:
SYCODFSEN1
Code 11 – Get All Pa-
rameter
SY
CO1
1
G
Returns all code 11 parameter values in
an XML element.
Example
: SYBCO11G
Code 11
SY
CO1
1
S/P/R/
G
EN
0
0
Disable
Example:
SYCO11SEN0
1
Enable
Example:
SYCO11SEN1