Configuration control
Leuze electronic
DCR 55
59
8.2.14 Setup camera parameters
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Test Mode
IM
CP
S/P/R/
G
TM
Example: IMCPG
Minimum Exposure (per-
cent)
IM
CP
S/P/R/
G
ME 20
0
Minimum Value
Defines the minimum exposure parame-
ter of camera
Valid Range:
0 to Maximum Exposure
percent
Example
: IMCPSME20
Maximum Exposure (per-
cent)
IM
CP
S/P/R/
G
XE
100
100
Maximum Value
Valid Range:
0 and Minimum Exposure
to 100 percent
Example
: IMCPSXE100
8.2.15 Command barcode format
The device can receive commands directly through user input, via serial or text and via configuration com-
mand barcodes. This section describes the format of configuration command barcodes.
Header
Command
Trailer
<SOH>Y<GS><STX>
(%01%59%1D%02)
String
<ETX><EOT>
(%03%04)
Multiple commands can be included in one configuration command barcode by separating each command
with <ETX>.
Example: Scanning a barcode generated from
%01%59%1d%02SYAZTCG%03SYAUPOG%03%04
will output
all settings of the AZTC and AUPO symbologies.
Configuration command barcodes:
• Configuration command barcodes use the QR code barcode symbology.
• Source files to generate configuration barcodes have a file extension of .CRCCS and an intermediate
file extension of .CRMKR.
• If source files contain comments, the comment should start with two forward slash (//) characters.
• Source files can have only one Primary Category command per line (see chapter 8.1 "Configuration
Examples:
• example.crccs
Contains:
// Hypothetical
// Outputs all settings of symbologies Aztec and Australian Post
// Rev 1 – 6/22/16 – Jackson – Initial Release
• example.crmkr
Contains:
%01%59%1d%02SYAZTCG%03SYAUPOG%03%04
• example.tif