Configuration control
Leuze electronic
DCR 55
46
Tab. 8.2:
HID language support
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Get all language parame-
ters
LA
IN
G
Get all language settings
Example: LAING
Active language
LA
IN
S/P/R/
G
AL
USEn-
glish_
Win
Active language setting
Valid Range:
Languages listed by the
LAINGIL command
Example:
LAINGAL
Get Installed languages list
LA
IN
G
IL
List installed language names
Example:
LAINGIL
Control character encoding
CM HD
S/P/R/
G
CC 0
0
Language Default
Example:
CMHDSCC0
1
C Character
Example:
CMHDSCC1
2
Alt + Keypad
Example:
CMHDSCC2
3
Alt + Leading 0
Example:
CMHDSCC3
Choose the control character encoding
style.
8.2.4
Packet and protocol parameters
Code Description
Command Format Op-
tions
De-
fault
Notes/Examples
Packet – Get All parameters PK
OP
G
Returns all packet parameter values in
an XML element.
Example
: PKOPG
Receive Timeout (ms)
PK
OP
S/P/R/
G
RT
250
When retry count specified and reader
doesn’t receive the ACK, it will resend
the response after the timeout.
In milliseconds
Valid Range:
Example
: PKOPSRT250
Connection Protocol Time-
out (s)
PK
OP
S/P/R/
G
CT
60
When sending fragmented data in
packet mode, this timeout specifies the
maximum time between two fragments.
Reader cancels the transaction when
the timeout expires and it didn’t receive
new fragmented data.
In Seconds
Valid Range:
Example
: PKOPSCT120
Reader Retry Count
PK
OP
S/P/R/
G
RC 0
Number of retries from the reader when
no ACK is received from the host.
Valid Range:
Example
: PKOPSRC1