Configuration control
Leuze electronic
DCR 55
26
8
Configuration control
This chapter specifies the configuration commands of the device.
Notations
The interface protocol is described as a set of grammars, indicated by different type styles and symbols.
Example
Indication
Grammar
Text-Command
Italic type
Syntactic categories (non-terminals)
space
Bold type
Terminal symbols
%xx
Byte data
In Hex
0xFF
0x prefix indicating hexa-
decimal
Literal byte values
‘X’
Single quotes
Literal ASCII characters
SOH
All caps
Non-printable ASCII characters
esc | tab
Vertical bar
Alternatives (this or that)
data
opt
opt.
(opt subscript)
Optional terminals and non-terminals
crc16
nr
nr
(nr subscript)
Applies to packets sent in non-raw mode, i. e. in
packet mode
8.1
Configuration command architecture
This section describes the format of configuration commands that the device will accept to change and
save configuration settings.
Command format
Primary cate-
gory
Sub-category
Action code
(S/P/R/G)
Parameter
Parameter value
(when actions is
S or P)
Example: SY,
CM, etc.
Example: AZTC,
SE, etc.
S – Change and save
P – Change but do not save
R – Reset to default value
G – Get value in effect
Example: AL,
BA , [ , etc.
String of decimal
number or text
Example: SYAZTCSPO1
This command sets the polarity to Inverse mode of the Aztec symbology and saves it to non-volatile mem-
ory. Breakdown of the command:
• SY = Symbology
• AZTC = Aztec
• S = Set
• PO = Polarity
• 1 = Inverse Mode