Online commands
Leuze electronic
BCL 8
61
TNT
35/7-2
4
V
Teach-In
Notice!
With this function, only code types are recognized that are identified using the autoConfig
function or which were set in the set-up.
After each reading via an ’RTy’ command, explicitly switch off the function again since
failure to do so will interfere with other commands as well as prevent execution of a new
’RTy’ command.
Command
’RT’
Description
This command enables a reference code to be defined quickly by reading
an example label.
Parameter
’RTy’
y
Function
’1’
Defines reference code 1
’2’
Defines reference code 2
’+’
Activates the definition of reference code 1 or 2
’-’
Exits the Teach-in process
Acknowledg-
ment
The BCL 8 first responds with the command
’RS’
and corresponding sta-
tus (see Command RS). After a bar code has been read, it sends the
result in the following format:
’RCyvxxzzzzz’
y
,
v, x
and
z
are placeholders (variables) for the actual input.
y
Def. reference code no.
’1’
(Code 1)
’2’
(Code 2)
v
Memory location for reference code
’0’
RAM+EEPROM
’3’
RAM only
xx
Def. code type (see Command ’CA’)
z
Def. code information (1 … 30 characters)