Online commands
60
BCL 8
Leuze electronic
Manual definition of the reference code
Command
RS
Description
This command can be used to define a new reference code in the BCL 8
by means of direct input via the serial interface. The data is saved in the
parameter set according to your input under reference code 1 or 2 and
stored in the working buffer for direct further processing.
Parameter
’RSyvxxzzzzzzzz’
y
,
v, x
and
z
are placeholders (variables) for the actual input.
y
Def. reference code no.
’1’
(Code 1)
’2’
(Code 2)
v
Storage location for reference code:
’0’
RAM+EEPROM
’3’
RAM only
xx
Def. code type (see Command ’CA’)
z
Def. code information (1 … 30 characters)
Acknowledg-
ment
’RSx’
x
Status
’0’
Valid ’Rx’ command
’1’
Invalid command
’2’
Insufficient memory for reference code
’3’
Reference code has not been saved
’4’
Reference code invalid
Example
Input = ’RS130678654331’
(Code 1 (1), RAM only (3), UPC (06), code information)