Installation
Leuze electronic
BCL 8
33
TNT
35/7-2
4
V
6.2
Mounting
Attention, laser radiation!
Follow the safety notices in chapter 2.5 on page 7!
Accessories
A variety of mounting systems are available which you can order separately from Leuze
electronic (see chapter 5.1 and chapter 5.4).
Mounting the BCL 8
There are three basic mounting arrangements for the BCL 8 (see chapter 4.3):
• using the dovetail strips and the corresponding mounting accessories BT 8-0.
• using the mounting threads on the back- and underside of the devices.
• using the two
∅
4.4mm through holes.
Mounting the MA 8.1 connector unit
You can mount the MA 8.1 connector unit according to your needs by using the two bore
holes. Subsequently, connect the BCL 8 with the connector unit via the respective cable
(see separate data sheet for MA 8.1).
6.2.1
Device arrangement
Selecting a mounting location
In order to select the right mounting location, several factors must be considered:
• size, orientation, and position tolerance of the bar codes on the objects to be scanned.
• the reading field of the BCL 8 in relation to the bar code module width.
• the resulting minimum and maximum read distance from the respective reading field
(For specific information, please refer to chapter 4.4).
• alignment of the bar code reader for avoiding reflections.
• distance between BCL 8 and host system with respect to the interface.
Notice!
The best reading results are obtained when
• the reading distance lies in the middle area of the reading field.
• there is no direct sunlight and extraneous light is avoided.
• the bar code labels are of good print quality and have good contrast ratios.
• you do not use high-gloss labels.
• the bar code is moved past the reading window with a rotational angle > approx. 15°.
• the laser beam is narrowed down for its respective reading task in order to avoid
reflections on shiny components.