DeviceNet interface
74
AMS 355
i
Leuze electronic GmbH + Co. KG
9.6.5.2 Output assembly
Attribute 2
The attribute provides an assembly for outputs. The EDS parameter "Output assembly" is
used to select an assembly which – after an arbitration cycle defined in the DeviceNet scanner
– automatically writes data to the AMS 355
i
with high priority.
Customers cannot create their own assemblies because they are part of the EDS file supplied
by Leuze.
A detailed description of the assemblies offered by Leuze can be found from Chapter 9.6.1.4.
Attention!
During project planning with RS Networx, Rockwell Automation requires configuration of the
storage area for the assemblies selected in object class 101. If the assemblies in object
class 101 are changed, the storage area in the scanner for assemblies must be adapted.
This is illustrated in the following screenshot from the RS Networx configuration tool: