DeviceNet interface
68
AMS 355
i
Leuze electronic GmbH + Co. KG
9.6.3.9 Alarms
Attribute 44
The PLB and ERR status messages generated by the AMS 355
i
are entered in bit 0 and bit 1.
The alarms entered here lead to incorrect measurement values at the AMS 355
i
. The CIP
specification makes a distinction between alarms and warnings.
The following applies for PLB and ERR:
0 = No alarm
1 = Alarm
9.6.3.10 Supported alarm
Attribute 45
Attribute 45 indicates which alarms specified by the position sensor object are supported by
the AMS 355
i
.
Bit 0 = 1; PLB alarm is supported by the AMS 355
i
.
Bit 1 = 1; ERR alarm is supported by the AMS 355
i
.
Bit 2 to bit 15 = 0
9.6.3.11 Alarm flag
Attribute 46
The attribute evaluates the alarms supported in attribute 45, in an OR function (collective
alarm).
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
ERR
PLB
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Vendor spec.
Reserved
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved
1
1
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Vendor spec.
Reserved