Electrical connection
38
AMS 355
i
Leuze electronic GmbH + Co. KG
Note!
Degree of protection IP65 is achieved only if the connectors and caps are screwed into place!
Described in detail in the following are the individual connections and pin assignments.
7.2
PWR – voltage supply / switching input/output
Table 7.1:
Pin assignments - PWR
Further information on configuring the input/output can be found in Chapter 8 and Chapter 9.
7.3
DeviceNet BUS IN
Table 7.2:
DeviceNet BUS IN pin assignment
PWR (5-pin connector, A-coded)
Pin
Name
Comment
1
VIN
Positive supply voltage
+18 … +30VDC
2
I/O 1
Switching input/output 1
3
GNDIN
Negative supply voltage 0VDC
4
I/O 2
Switching input/output 2
5
FE
Functional earth
Thread
FE
Functional earth (housing)
PWR
I/O 2
I/O 1
3
2
1
4
5
GND
VIN
FE
M12 connector
(A-coded)
BUS IN (5-pin connector, A-coded)
Pin
Name
Comment
1
Drain
Shield
2
V+
Data V+ supply voltage
3
V-
Data V- supply voltage
4
CAN_H
Data signal CAN_H
5
CAN_L
Data signal CAN_L
Thread
FE
Functional earth (housing)
BUS IN
V+
CAN_H
1
4
3
2
5
DRAIN
V-
CAN_L
M12 connector