![Leuze electronic AMS 355i Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/leuze-electronic/ams-355i/ams-355i_original-operating-instructions_1883973062.webp)
DeviceNet interface
Leuze electronic GmbH + Co. KG
AMS 355
i
59
TNT
35/7-2
4V
The automatically performed parameter download (Configuration Recovery activated)
causes a parameter change to be reversed immediately after deactivation of parameter
enable in the AMS 355
i
.
Attention!
If the "Configuration Recovery" function is not activated, the parameters changed via the dis
-
play apply. The parameters are not overwritten automatically.
As before, it is possible to manually download the parameters stored in the control.
Note!
In the following tables, all attributes marked in the "Access" column with "Get" in the individual
objects are to be understood as inputs of the scanner (control). E.g. "Read in the position
value" --> Class 35; instance 1; attribute 10.
Attributes marked in the "Access" column with "Set" represent outputs or parameters. Out
-
puts are set, e.g. "Laser off"--> Class 35; instance 1; attribute 110.
Parameters are also marked with "Set" and written to the AMS. E.g. "Change the position
format" --> Class 35; instance 1; attribute 15.