DeviceNet interface
62
AMS 355
i
Leuze electronic GmbH + Co. KG
9.6.1.4 Preset value + control
Instance 120, attribute 3
Output assembly: length 5 bytes
Leuze-specific assembly
Byte 0 - Byte 3: preset value
Byte 4: preset control
Note!
Negative values are shown in two's complement.
9.6.2
Class 1 Identity object
Object class 1 = 01
H
Services:
• Get Attribute Single
• Reset type 0
Path
Designation
Size
in bit
Data type Default
(dec)
Min.
(dec)
Max.
(dec)
Acces
s
Cl.
Inst. Attr.
4
120
3
Preset value
32
DINT
-
-214742147483648
Set
Preset control
8
Byte
-
0
3
Set
Inst. Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit0
120
0
Preset value (low byte)
1
Preset value
2
Preset value
3
Preset value (high byte)
4
0
0
0
0
0
0
Preset
reset
1 = ON
0 = OFF
Preset
teach
1 = ON
0 = OFF
Path
Designa
-
tion
Size
in bit
Data type
Default
(dec)
Min.
(dec)
Max.
(dec)
Access
Cl.
Inst. Attr.
1
1
1
Vendor ID
16
UINT
524
-
-
Get
2
Device type
16
UINT
34
-
Get
3
Product
Code
16
UINT
1002
-
Get
4
Revision
(Major,
Minor)
16
Struct{
USINT major,
USINT minor};
Major = 1,
Minor = 1
Major = 1,
Minor = 1
Major =
127,
Minor = 999
Get
5
Status
16
WORD
See CIP specification
(5-2.2.1.5 status)
Get
6
Serial
Number
32
UDINT
Manufacturer specific
Get
7
Product
Name
(max. 32)
x 8
SHORT_STRI
NG
"AMS 355i"
Get