EtherCAT interface
Leuze electronic
AMS 338
i
77
TNT
35/7-2
4
V
9.7.6.17 Object 2300
h
Other
Notice
!
Password activation must be set to ON.
Explanation on sub-index 06 "heating control"
0 = Standard (10°C … 15°C)
1 = Extended (30°C … 35°C)
Notice
!
The sub-index 06 is available as standard, but functions only for devices with integrated heat-
ing (AMS 338
i
… H).
Sub-index 06 defines a switch-on/switch-off range for the heating control. The extended
switch-on/switch-off range for heating may provide relief in the event of condensation prob-
lems. There is no guarantee that no condensation will occur on the optics in the extended
switch-on/switch-off range due to the limited heating capacity.
9.7.7
Objects of the AMS 338
i
from the DS406 class 1 encoder profile
The AMS 338
i
adopts the profile from CANopen. The profile puts prescribed characteristics
of the participant on defined object addresses.
The AMS 338
i
communicates according to the specifications in profile "DS406" class 1.
For class 1, it is mandatory to describe the following objects.
Index
Sub-
index
Name
Data type
Access
Value range
Remark
(hex)
(hex)
Minimum
Maximum
Default
2300
01
Display lan-
guage selec-
tion
u8
rw
0
4
0
0 = English
1 = German
2 = Italian
3 = Spanish
4 = French
02
Illumination
duration dis-
play
u8
rw
0
1
0
0 = off after
10min.
1 = always on
03
Display
contrast
u8
rw
0
2
1
0 = low
1 = medium
2 = high
04
Password
activation
u8
rw
0
1
0
0 = OFF
1 = ON
05
Password
u16
rw
0000
9999
0000
Setting of a
4-digit password
06
Heating con-
trol
u8
rw
0
1
0
see below