EtherCAT interface
Leuze electronic
AMS 338
i
69
TNT
35/7-2
4
V
Bit 2: movement status
0 = positive direction
1 = negative direction
Bit 3: velocity limit value status 1
0 = limit value maintained
1 = limit value violated
Bit 4: velocity limit value status 2
0 = limit value maintained
1 = limit value violated
Bit 5: velocity limit value status 3
0 = limit value maintained
1 = limit value violated
Bit 6: velocity limit value status 4
0 = limit value maintained
1 = limit value violated
Bit 7: velocity limit value status dynamic
0 = limit value maintained
1 = limit value violated
Bit 8: velocity comparison limit value 1
0 = comparison inactive
1 = comparison active
Bit 9: velocity comparison limit value 2
0 = comparison inactive
1 = comparison active
Bit 10: velocity comparison limit value 3
0 = comparison inactive
1 = comparison active
Bit 11: velocity comparison limit value 4
0 = comparison inactive
1 = comparison active
Bit 12: velocity comparison limit value dynamic
0 = comparison inactive
1 = comparison active